Prowirl 77 manual pdf

Prowirl 77 w wafer prowirl 77 f flanged prowirl 77 with local programming prowirl 77. The flowmeter for accurate steam flow measurement with wet steam detection, available as compact or remote version. Its calibration option premiumcal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. Prowirl 70, 77 prowirl 72 oder 73 prowirl 72 prowirl 73. The prowirl d sensor can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. Functional safety manual proline prowirl 72, 73 with 4. Automatic creation of the order code and its breakdown in pdf or excel. Dedicated for applications with very low or reduced flow. Technical information vortexflowmeasuringsystem prowirl77.

Integrated temperature measurement for massenergy flow of saturated steam. Proline prowirl 200 functional safety manual special. The prowirl 200 is the most robust vortex flowmeter available on the market. If the process pressure and temperature at the measuring point are constant and accurately known, prowirl 77 can also be programmed to display the flow rate in these units. Differential switched capacitance dsc sensor with high immunity to thermal shock and pipe vibration. The robust and safe flowmeter, suitable for applications up to sil 2. Vortex meters require a fully developed flow profile as. Prowirl 200 vortex flowmeter for energy measurement. The transmitter brief operating instructions are aimed at specialists with. Looppowered compact version, protection type nema 4x ip67. With genuine looppowered technology, prowirl f 200 enables costeffective and seamless integration into existing infrastructures.

Proline prowirl f 200 7f2c proline prowirl f 200 7f2c. With genuine looppowered technology, prowirl d 200 enables costeffective and seamless integration into existing infrastructures. Prowirl 72, vortex measuring system controls warehouse. Cost and time saving no pipework modifications needed for line size reduction. These brief operating instructions explain how to commission your.

Vortex flow measuring system for reliable flow measurement of gas, steam and liquids. Industrial, flanged vortex flowmeter for the flow measurement of gas, liquid or steam. Prowirl 70, 77 proline prowirl 72 and 73 vortex flow. The following instructions must therefore be observed when installing prowirl. Proline prowirl o 200 7o2c proline prowirl o 200 7o2c. Inlet run correction inlet run correction makes it possible to shorten the necessary inlet run before the measuring device to a minimum length of 10. Smart microprocessorbased flanged vortex shedding flowmeter for measuring liquid, gas or steam flow. Costeffective wafer design, available as compact or remote device version. The vortex revolution for steam, gas and liquid robust, multifunctional, proven. Prowirl 77 and additional pressure and temperature transmitters. Prowirl 70 transmitter compact or remote prowirl w, f, h, or d meter body see page 3 the high performance, universal prowirl 70 transmitter can be freely combined with the various. Proline prowirl 72 vortex flow measuring system surplus select.

Industrial vortex flowmeter for the flow measurement of gas, liquid or steam. Please comply with the special mounting instructions when using pressure transmitters. Technical information proline prowirl 73 reliable flow measurement of gas, steam and liquids. For detailed information on the parameters, see the operating instructions. The prowirl 200 is optionally available with a wet steam measurement. When measuring steam mass or energy content, a vortex flowmeter is paired with a pressure or temperature sensor, and a flow computer. Transmitter all prowirl 77 transmitters have the following features. Proline prowirl f 200 vortex flowmeter these instructions are brief operating instructions.

Vortex flow measuring system for measuring gas, steam and liquids version. Current 420 ma and programmable passive open collector pulse outputs xpex d versions without pulse output. Proline prowirl f 200 measuring instruments pdf manual download. Proline prowirl 72 measuring instruments pdf manual download. Technical information vortex flow measuring system prowirl 77. Controllogix hart analog io modules user manual, publication. Steam, gas, and the most varied liquids play an important role in all.

On the cdrom supplied is not included in the delivery for. When fluid flows past a bluff body, vortices are alternately formed on both sides with opposite directions of rotation. If the process pressure and process temperature are constant, the measuring device can also output the flow as the calculated mass flow. Prowirl 77 measuring instruments pdf manual download. A mounting set is recommended to ensure concentric wafer mounting must be ordered separately differential switched capacitance dsc sensor with high immunity to thermal shock and pipe vibration. Application for universal volume or mass flow measurement of steam, water according to iapwsif97 asme, natural gas according to aga nx19, compressed air and other liquids or gases. For all basic applications and for 1to1 replacement of orifice plates. You will find a flowchart of the commissioning quick setup menu on page 41 and the function description on page 77. Technical vortex flow measuring system information prowirl 70. The prowirl uses the triedandtested capacitance measuring technology of. Smart microprocessorbased vortex flowmeter for measuring liquid, gas or steam flow. All vortex flowmeters measure the volumetric flow of liquids, gases and steam, but are often particularly favored for steam measurement. It offers highest operational safety in hazardous areas.

1204 1502 995 963 772 730 1459 80 809 266 238 1232 1427 367 688 1114 1532 614 776 1084 149 1068 13 1108 1009 1257 129 414 645 1468 982 754 889 166 1382 1322 676 429